Wacker Neuson E1250
Wacker Neuson E1250
Heating Units

Wacker Neuson E1250

E1250

Simple, safe, and intelligent

The E 1250 was designed with the safety features you require and the simple, intelligent operation you desire. All operator interface points are conveniently located in the rear of the machine for simplified operation. Our new concrete cure mode simplifies the guesswork in maintaining proper concrete temperature, and our user-friendly control panel incorporates a watchdog circuit, E-Stop, and single point reset for the most common faults. All versions are telematics ready.

  • The E 1250 is engineered for reliable performance and trouble-free starts with large 74 gallon fuel tank for up to 115 hours of run time at 87% efficiency. With thawing capabilities of up to 2,500 sq. ft. of frozen ground at an average rate of one-foot-deep per day*, the E 1250 will set, finish and cure 2,500 sq. ft. of concrete or up to 7,500 sq. ft. with accessories (standard model only).
  • Positive displacement pumps provide the pressure needed to deliver hot fluid to bridge decks, high-rises and other elevated applications. An integrated temperature sensor prevents cold starts to the pump, ensuring maximum pump longevity.
  • Control panel includes large, low-voltage toggle switches, heated 5" backlit display for showing machine status, GFCI protection, and advanced diagnostics mode for quick troubleshooting. The optional telematics package allows for remote monitoring of the jobsite.
  • The Basic model offers simplified operation with the performance you require at a value price. Features include convenient fork pockets and a 2” ball hitch for easy jobsite maneuverability, added simplicity of pre-warming and leak checking the hose while on the machine, and advanced diagnostics to minimize downtime.
  • The Standard model includes a 4.2 kW Kubota powered liquid cooled generator with wet-stacking protection, 2-point lift bail, dual-color performance monitoring strobe light, rear expansion ports and digital sensing of fuel and HTF pressure. Additionally, the Premium model adds -40° package with in-line fuel heater, spill containment, upgraded pump, and upgraded trailer jack.

specifications

  E 1250B, Diesel E 1250B, NG/LP E 1250S, Diesel E 1250S, NG/LP

Dimensions 

L x W x H  in 140 x 76 x 68 140 x 76 x 68 140 x 76 x 72 140 x 76 x 72
Operating weight  lb 3,175 3,175 3,775 3,775
Shipping weight w/trailer (no fuel) lb 2,730 2,730 3,330 3,330
Heat transfer fluid Capacity US gal 54 54 54 54
Hose length ft 1250 1250 1250 1250
Quantity Hose reels 1 1 1 1
Quantity Circulation Loops 1 1 1 1
Temperature monitor  Digital Digital Digital Digital

Operating data 

Flow velocity Heat transfer US gal/h 265 265 265 265
Hose pressure Normal Operating psi 110 110 110 110
Heating power Gross input BTU/h 140,000 140,000 140,000 140,000
Heat efficiency  % 87 83 87 83
Operating temperature  ° F 100 200 200 200
Capacity Thaw (std) ft² 2,500 2,500 2,500 2,500
Capacity Thaw (w/acc) ft²     3,750 3,750
Capacity Cure (std) ft² 2,500 2,500 2,500 2,500
Capacity Cure (w/acc) ft²     7,500 7,500
Capacity Frost prevention (std) ft² 3,750 3,750 3,750 3,750
Capacity Frost prevention (w/acc) ft²     11,250 11,250
Capacity Air heat capacity (w/acc) ft³     203,600 203,600
Current  A 15 15 15 15
Rated voltage AC Voltage V 120 120 120 120
Engine / Motor manufacturer      Kubota Z602  
Engine / Motor type      2-cylinder Liquid-cooled  
Displacement  in³     36.55  
Engine performance  hp     16.8  
Engine RPM  rpm     1800  
Fuel type  #2 winter blend diesel LP/NG #2 winter blend diesel LP/NG
Fuel consumption Diesel US gal/h 1   1.18  
Fuel consumption (natural gas) Burner ft³/h   140   140
Fuel consumption (liquid propane) BurnerUS gal/h   1.53   1.53
Tank capacity Useable US gal 68 68 68 68
Runtime at 100% h 68 68 68 68
Runtime at 75% h 90 90 90 90
  E 1250P, Diesel E 1250P, NG/LP

Dimensions 

L x W x H  in 140 x 76 x 72 140 x 76 x 72
Operating weight  lb 3,992 3,992
Shipping weight w/trailer (no fuel) lb 3,465 3,465
Heat transfer fluid Capacity US gal 54 54
Hose length ft 1250 1250
Quantity Hose reels 1 1
Quantity Circulation loops 1 1
Temperature monitor  Digital Digital

Operating data 

Flow velocity Heat transfer US gal/h 265 265
Hose pressure Normal operating psi 110 110
Heating power Gross input BTU/h 140,000 140,000
Heat efficiency  % 87 83
Operating temperature  ° F 200 200
Capacity Thaw (std) ft² 2,500 2,500
Capacity Thaw (w/acc) ft² 3,750 3,750
Capacity Cure (std) ft² 2,500 2,500
Capacity Cure (w/acc) ft² 7,500 7,500
Capacity Frost Prevention (std) ft² 3,750 3,750
Capacity Frost Prevention (w/acc) ft² 11,250 11,250
Capacity Air Heat Capacity (w/acc) ft³ 203,600 203,600
Current  A 15 15
Rated voltage AC Voltage V 120 120
Engine / Motor manufacturer  Kubota Z602 Kubota Z602
Engine / Motor type  2-cylinder Liquid-cooled 2-cylinder Liquid-cooled
Displacement  in³ 36.55 36.55
Engine performance  hp 16.8 16.8
Engine RPM  rpm 1800 1800
Fuel type  #2 winter blend diesel LP/NG
Fuel consumption Diesel US gal/h 1  
Fuel consumption (natural gas) Burner ft³/h   140
Fuel consumption (liquid propane) Burner US gal/h   1.53
Tank capacity Useable US gal 68 68
Runtime at 100% h 68 68
Runtime at 75% h 90 90