Efficient, versatile and reliable, the HI 200 portable indirect fired air heaters produce clean, dry, healthy heat offering an ideal environment for a variety of construction, residential and restoration applications without the use of an open flame, combustion carbons or water. The HI 200 can handle various heating and drying applications with 205,000 BUT's/hr and over 84% efficiency. Large pneumatic tires and extended run time fuel tanks make these portable air heaters ideal for any jobsite and are CSA approved
- Available in Standard or Heavy Duty (HD) models.
- Low temperature rating to -20 degrees C on standard model; -40 degrees C on Heavy Duty (HD) model.
- Heavy Duty model includes robust structural support including under heater cross support and 4 point lifting brackets.
- Control panel on the heater offers convenient side outlet for attaching remote thermostat for maintaining ideal temperature range.
- Accessories include remote thermostat, ductwork, L-vent pipe and rain cap.
Specifications
HI 200D | HI 200HD D | |
---|---|---|
Dimensions |
||
L x W x H Overall in | 65.4 x 30.0 x 38.6 | 65.4 x 30.0 x 38.6 |
L x W x H Shipping in | 64.2 x 25.8 x 37.9 | 64.2 x 25.8 x 37.9 |
Weight Dry lb | 240 | 240 |
Operating weight with Fuel lb | 437 | 437 |
Operating data |
||
Diameter Flue in | 6 | 6 |
Diameter Air Outlets (Qty 2) in | 12 | 12 |
Heating power Gross Heat Input BTU/h | 204,873 | 204,873 |
Heating power Net Heat Output BTU/h | 173,117 | 173,117 |
Heat efficiency HHV % | 84.5 | 84.5 |
Operating temperature Heat Rise (at 68° F) ° F | 136 | 136 |
Capacity Sizing Air Heat ft³ | 6,490 | 6,490 |
Capacity Drying Size ft³ | 2,054 | 2,054 |
Fuel type | Diesel #2, Kerosene | Diesel #2, Kerosene |
Fuel consumption no genset US gal/h | 1.48 | 1.48 |
Tank capacity Fuel US gal | 27.9 | 27.9 |
Runtime 100% Burner run percentage h | 18.7 | 18.7 |
RPM / speed burner rpm | 3,300 | 3,300 |
Air flow CFM | 1,530 | 1,530 |
Static Pressure W.C. (inch) | 0.5 | 0.5 |
Length Max Duct 1 x 14 Supply Adapter ft | 50 | 50 |
Length Max Duct 2 x 12 Supply Adapter ft | 25 | 25 |
Electrical system |
||
Frequency Hz | 60 | 60 |
Voltage V | 120 | 120 |
Current A | 15 | 15 |
×