Wacker Neuson G 230
Wacker Neuson G 230
Generators

Wacker Neuson G 230

G 230

Serious generators for serious power applications

 

Mobile generators provide durable sound attenuated mobile prime power for larger industrial, commercial, construction, special event and emergency management applications where quiet reliable power is needed. The G 230 offers ultra clean burning diesel and is especially suited for areas requiring BAT (Best Available Technology) to meet the most stringent EPA, CARB air standards. A digital controller monitors and protects the generator and engine while providing continuous operating data on and easy to read LCD display. Large fuel tanks provide for convenient long run times.

  • Brushless oversized alternators and separate excitation winding and AVR (Automatic Voltage Regulation) provide superior motor starting and enhanced ability to run non-linear loads.
  • Single switch start and simple uncluttered control panel provide unmatched ease of use.
  • Easy voltage selection using a lockable voltage selector switch reduces connection errors.
  • Standard environmentally friendly "green" features include 115% fluid containment, crankcase oil vapor recovery system, no mess oil and radiator drain hoses/valves and fast fuel fill system (50 gpm).
  • Heavy-duty, tandem-axle trailers with aluminum diamond plate fenders are road ready with DOT lighting, chains, height adjustable coupler, choice of surge or electric brakes.

Specifications

    G 230 (T4i) Canada only G 230 (T4F)

Dimensions 

L x W x H Operating (Skid) in   132 x 52 x 74.5 132 x 52 x 76.5
L x W x H Shipping (Skid) in   135.5 x 54.5 x 88 135.5 x 54.5 x 88
L x W x H Shipping/Operating (Trailer) in   199 x 84.5 x 104.5 199 x 84.5 x 106.5

Weights 

Weight Dry (Skid) lb   6,500 7,100
Weight Operating (Skid) lb   9,220 10,200
Weight Shipping (Skid) lb   6,867 7,467
Weight Operating (Trailer) lb   10,700 11,680
Weight Shipping (Trailer) lb   7,980 8,580

Operating data 

Trailer coupling Type   Pintle Pintle
Standby output   kW   202 202
Prime output  kW   184 184
Voltage 3 Phase V   240/480 240/480
Current 3 Phase (Prime) A   553/277 553/277
Voltage 3 Phase V   208, 220, 240, 416, 440, 480 208, 220, 240, 416, 440, 480
Voltage 1 Phase V   120, 127, 139, 240, 254, 277 120, 127, 139, 240, 254, 277
Circuit breaker (Main) A   700 700
Frequency  Hz   60 60
Power factor 1 Phase cos Φ 1~   1 1
Power factor 3 Phase cos Φ 3~   0.8 0.8
Sound level (LwA) at Prime (23 ft / 7 m)dB(A)   73 73.5
Receptacles -20 Amp GFI Duplex   2 2
Receptacles -50 Amp Twist Lock   3 3

Engine / Motor 

Engine / Motor    Liquid-cooled, 6 Cylinder Liquid-cooled, 6 Cylinder
Engine / Motor manufacturer    Cummins Cummins
Emissions Certified   Tier 4i Tier 4F
Displacement  in³   409 409
Operating performance ISO 3046 hp   314 314
Operating performance SAE J1995, ISO 8528-1 hp      
at rpm  rpm   1,800 1,800
Coolant Capacity US qt   31 65.2
Engine oil Capacity US qt   18.5 18.5
Fuel type    Diesel #1/#2 ULSD
Fuel consumption (Prime Load) US gal/h   13.6 13.6
Tank capacity -Fuel US gal   377.7 381.4
Quantity (Battery)   2 2
Battery  V   12 12
Generator model    Mecc Alte, Brushless w/AVR Mecc Alte, Brushless w/AVR
Voltage control No Load to Full Load +/- %   1 1
Voltage control Steady State +/- %   0.2 0.2
Generator insulation (class)    H H
Frequency (Generator Speed) Hz   60 60
Runtime at 100% Prime Load h   26.1 26.1
Runtime at 75% Prime Load h   33.9 33.9
Runtime at 50% Prime Load h   47.3 47.3
Runtime at 25% Prime Load h   75.1 75.1
DEF Type      AUS 32
DEF Consumption  US gal/h     0.54
DEF Tank Capacity  US gal     37.4
Runtime  h     65.9