Wacker Neuson E5000
Wacker Neuson E5000
Heating Units

Wacker Neuson E5000

E5000

One hydronic heater, multiple applications

The most versatile hydronic surface heater, the E5000 thaws, cures, prevents frost, heats and dries all without the use of additional pump packs. The unique pump system provides maximum flow rate regardless of the application. The E5000 thaws or cures up to 10,000 sq. ft. With accessories, this machine will cure up to 30,000 sq. ft., heat up to 1,700,000 cu. ft. or provide 576,000 cu. ft. of dry heat with up to 64 hours of run time.

  • The E5000 is engineered for reliable performance and trouble-free starts for up to 64 hours of run time at 83% efficiency, the highest in the industry.
  • With 5,000 ft. of hose and a hydraulic hose system, the E5000 allows for single person set-up and placement, for greater flexibility on all applications.
  • Powerful pump system provides all the flow and pressure to deliver maximum performance for thaw, cure and air heat applications.
  • Digital temperature controller with push button adjustment allows operators to easily adjust Heat Transfer Fluid (HTF) output temperature for all concrete curing applications.
  • The E5000 offers 3 fuel options; diesel, natural gas or propane, for maximum job site convenience. Other options include a 12 kW liquid-cooled diesel generator.

Specifications

  E5000 Diesel E5000 Diesel W/Generator E5000 NG/LP

Dimensions 

L x W x H  in 189 x 98 x95 189 x 98 x95 189 x 98 x95
Operating weight  lb 10,700 12,100 10,700
Shipping weight  lb 8,925 10,399 8,925
Heat transfer fluid  US gal 210 210 210
Hose Length ft 5000 5000 5000
Quantity Hose Reels 2 2 2
Quantity Ciculation Loops 4 4 4
Temperature monitor  Digital Digital Digital

Operating data 

Pump Qty 2 US gal/h 3,000 3,000 3,000
Pump Qty 1 US gal/h 2,096 2,096 2,096
Flow velocity per circulation loop US gal/h 6.4 6.4 6.4
Hose pressure Normal Operating psi 117 117 117
Heating power Gross Input BTU/h 860,000 860,000 860,000
Heat efficiency  % 83 83 83
Operating temperature  ° F 180 180 180
Capacity Thaw (Std) ft² 5,000 5,000 5,000
Capacity Thaw (w/acc) ft² 10,000 10,000 10,000
Capacity Cure (Std) ft² 10,000 10,000 10,000
Capacity Cure (w/acc) ft² 30,000 30,000 30,000
Capacity Frost (Std) ft² 15,000 15,000 15,000
Capacity Frost (w/acc) ft² 45,000 45,000 45,000
Capacity Air Heat (w/acc) ft³ 1,433,333 1,433,333 1,433,333
Engine performance Generator kW   12  
Current 1 Receptacle each @ A 15/50 15/50 15/50
Voltage  V 120/240 120/240 120/240
Fuel type  Winter Blend Diesel Winter Blend Diesel Natural Gas, Propane (HD-5)
Fuel consumption Diesel US gal/h 6.14 6.14  
Fuel consumption (natural gas)  ft³/h     860
Fuel consumption (liquid propane)  US gal/h     9.5
Tank capacity  US gal 235 235  
Runtime @ 100% Burner Run Percentageh 36 36  
Runtime @ 75% Burner Run Percentageh 48 48